Variabilidad de factores agroclimáticos y el gasto de riego en el cultivo protegido del pimiento (Capsicum annuum)

Resumen

El presente trabajo tuvo como objetivo determinar la relación entre la uniformidad del caudal de riego y la variabilidad de los factores agroclimáticos con el rendimiento durante el cultivo del pimiento en casas de cultivo. El estudio se llevó a cabo en un módulo de tres casas de cultivo protegido modelo Granma-1, perteneciente a la Empresa Agropecuaria "Valle del Yabú", en la provincia Villa Clara sobre suelo pardo con carbonatos. Dentro de cada casa se conformaron seis canteros con tres ramales de riego con goteros no autocompensantes modelo Twin Drip. Para el estudio se tomaron 27 puntos de muestreo, distribuidos uniformemente en las tres casas de cultivo. La velocidad del viento, temperatura y humedad relativa se midieron con la micro estación meteorológica Kestrel 5000. Para el muestreo del gasto de los goteros se instalaron pluviómetros en cada punto experimental y se determinó el coeficiente de uniformidad. Como resultado se evidenció que la velocidad del viento, la humedad relativa y la temperatura en el interior de la casa de cultivo mostraron valores de variabilidad espacial que satisfacen los requerimientos del cultivo. El coeficiente de uniformidad del gasto de riego obtuvo un valor de 71,2%, catalogándose de aceptable, como consecuencia de la obstrucción de goteros y denotando una amplia variabilidad del gasto en el área cultivada sin la presencia de encharcamiento ni zonas de suelo seco.

Abstract

The objective of the present work was to find the relationship between uniformity of irrigation flow and agro-climatic factors with the yield, during pepper growing in greenhouse. The study was carried out in a three modules of protected house Granma-1 model, placed at “Valle del Yabú" Agricultural Company, in the Villa Clara province over brown with carbonates soil. Inside each greenhouse sections, six soil beds were formed with three irrigation branches with non-compensating Twin Drip drippers. For the study, 27 sampling points were taken, evenly distributed in the three cultivation houses. The wind speed, temperature and relative humidity were measured with the Kestrel 5000 micro weather station. For the sampling of dripper flow, rain gauges were located at each experimental point and the irrigation coefficient of uniformity was determined. As a result, wind speed, relative humidity and temperature, inside the cultivation house, showed spatial variability values that satisfy the crop requirements. The coefficient of uniformity of irrigation rate was considered as acceptable with value of 71.2%, as a consequence of the obstruction of drippers, denoting a wide variability of irrigation rate without the presence of water flood or dry soil.

Sobre el ponente

Elvis López Bravo

Dr. Elvis López Bravo

UCLV Flag of Cuba


Discussion

Información Práctica
Ponencia
Spanish / Español
noviembre 14, 2023 12:50 p. m.
15 minutos
Salón 2 Starfish
Autores
Dr. Elvis López Bravo
Arley Placeres Remior
Omar González Cueto
Emily Carbonell Saavedra
Arturo Martínez Rodríguez
Palabras clave
drip
goteo
humedad.
moisture.
soil
suelo
temperatura
temperature
viento
wind
Documentos